Laboratory Exhaust Systems
Why use the Greenheck Vektor Laboratory Exhaust System? 
The main objective of a laboratory exhaust system is to remove hazardous or noxious fumes from a laboratory, dilute the fumes as much as possible, and expel them from the laboratory building so that the fumes do not contaminate the roof area nor are re-entrained into the building make-up air system.
The Greenheck Vektor high plume dilution blower is a self-contained laboratory exhaust system which offers the following benefits:
- Significant plume rise without unsightly exhaust stacks that detract from the building aesthetics
- Significant dilution of laboratory exhaust effluent, reducing levels of contaminant concentration
- Inline mixed flow or side inlet centrifugal arrangements
- Reliable belt or direct drive systems
- Efficient and quiet blower technology
- Unique "vacuum shaft seal" (Vektor-MD) ensuring that hazardous or noxious fumes do not escape through the shaft opening (patent pending)
- AMCA class C or B spark resistant construction
- L10-200,000 hour minimum life fan shaft bearings
- Premium high efficiency motor, standard
- Application to constant or variable volume exhaust systems
- Efficient discharge nozzle design
- LabCoat, a two-part corrosion resistant baked polyester resin coating with zinc rich epoxy primer
- Safe and easy maintenance
- Flow applications from 1,500 - 90,000 cfm at up to 14 in. wg per fan
- Multiple fan assemblies on a factory provided common plenum
- Meets ANSI Z9.5, NFPA 45, UL 705, and ASHRAE Chapter 44 lab design guidelines.
Advantage - Ease, Flexibility, Efficiency, Reliability
- Keeping a low profile - compact Vektor rooftop units achieve significant plume rise without detracting from buildings' aesthetics
- Ensuring safety - high-velocity plume displaces the lab effluent high above the roof, reducing the possibility of contamination of the building's interior, exterior and surrounding neighborhood
- Systems are designated to be fast and easy to install. And, maintenance is safe and easy because all critical access components are easily accessible without disassembling the entire system
- Single source responsibility - Greenheck is a single source for laboratory exhaust fan systems and laboratory exhaust energy recovery systems
- Validated performance - the Vektor system designs undergo state-of-the-art computational fluid dynamics and performance analysis.
Project Profile
Click
here to download a Project Profile of Kansas Life Sciences
Innovation Center in Kansas City, KS using the Vektor-MD Laboratory
Exhaust System.
Click
here to download a Project Profile of Texas Tech University
Institute of Environmental and Human Health facility in Lubbock,
TX using the Vektor-H (Model TCB-LE) Laboratory Exhaust System.